LifeCare Respironics PLV-102b

Microprocessor controlled portable volume ventilator that is capable of ventilating a wide range of patients. Suited to transport and portable applications due to its small size. Capable of ventilating pediatric and adult patients.

  • Control and Control-Assist Modes with optional Sigh and SIMV mode.
  • Six Alarm Codes assist in troubleshooting.
  • Adjustable from -6 to +18 cm H2O, which allows for use of PEEP up to 20 cm H2O.
  • Automatic, Continuous Sensitivity Corrections for barometric pressures changes.
  • Multiple Power Sources include 120 volts AC, an internal 12 volt DC battery and an external 12 volt DC battery.
Category:

Description

Dimensions

  • Height: 9 in (22.9 cm)
  • Width: 12.25 in (31.1 cm)
  • Depth: 12.25 in (31.1 cm)
  • weight: 28.9 lbs (31.1 g)

Power

  • 120 VAC 50/60 Hz
  • 12 VDC External Battery
  • 12 VDC Internal Battery

Front Panel Controls

  • Mode Selection: Control, Control + Sigh, Assist/Control, Assist/Control + Sigh, SIMV
  • Tidal Volume: 0.05 to 0.20 ± 0.02 liters; 0.20 to 3.00 liters ± 10%
  • Sign Volume: 150% of Set Tidal Volume
  • Sign Frequency: 1 Sign Breath every 100 Tidal
  • Breath Rate: 2 to 35 BPM ± 0.5; 36 to 40 BPM ± 2
  • Inspiratory Flow Rate (Peak flow rate during inspiratory time): 10 to 120 LPM
  • Battery Test Switch: Test Internal/External Battery
  • Main Power Switch: On/Off, Recharge
  • DC Circuit Breaker: Push/Pull Actuation
  • AC Circuit Breaker: Push/Pull Actuation
  • Airway Pressure Limit: 5 to 100 cm H2O ± 5
  • Sensitivity: +18 cm H2O ± 1 to at least -6 cm H2O
  • Low Pressure Alarm: 2 to 40 cm H2O ± 2; 41 to 50 cm H2O ± 5
  • Manual Sigh: Push to Activate One Breath
  • Oxygen Percent (See Operators Manual for Oxygen Delivery Limitations): 21% to 90% ± 6%
  • Oxygen Sensor – SIMV Operation (See Operators Manual for Oxygen Delivery Limitations): 21% to 90% ± 10%
  • 30 Second Alarm Silence: Push to Activate

Front Panel Visual Indicators

  • Manual Sigh: Yellow Indicator Light
  • Tidal Volume: Digital Display
  • Rate: Patient Breaths Per Minute – Digital Display
  • I:E Ratio: Digital Display
  • Inspiratory Flow Rate: Digital Display
  • Increase Inspiratory Flow: Red Indicator Light
  • 120 VAC Power Source: Green Indicator Light
  • Patient Airway Pressure: -10 to 100 cm H2O ± 5 (Pressure waveform is sinusoidal)
  • Internal DC Power Source: Amber Indicator Light
  • External DC Power Source: Yellow Indicator Light
  • Assisted/Spontaneous: Green Indicator Light
  • 15-Second Delay (Low Pressure Alarm): Green Indicator Light
  • Oxygen Percent: 50% and Greater Marked Red
  • 30-Second Alarm Silence: Yellow Indicator Light/Push Button
  • Alarm Code Display (in Flow Window): Digital Display

Alarms

  • Low Pressure: Visual/Continuous Audible
  • High Pressure: Intermittent Audible
  • Apnea: Visual/Continuous Audible
  • Inverse I:E Ratio: Visual Warning
  • Increase Inspiratory Flow: Visual Warning
  • Reverse Battery Connection: Continuous Audible
  • Low Internal Battery: Visual/Continuous Audible
  • Low External Battery: Visual/Continuous Audible
  • Power Failure: Continuous Audible
  • Unit Malfunction: Intermittent Audible
  • Power Source Change: Continuous Audible
  • Oxygen: Continuous Audible