l

Ut wisi enim ad minim veniam, quis laore nostrud exerci tation ulm hedi corper turet suscipit lobortis nisl ut

Recent Posts
2643-G and H Taft Avenue Pasay City Manila, PH 1300
26846 Oak Avenue Unit C Canyon Country, CA 91351
Image Alt

Bear Cub 750 PSV

The BEAR CUB™ 750 PVS ventilator can be classified as a microprocessor controlled, time cycled, pressure limited, dual flow, neonatal/pediatric critical care ventilator. Breaths are initiated either by the ventilator (controlled), by patient activity (assisted), or by the operator (manual).

  • Pneumatic Ventilator
  • Gas Inlet Conditioning
  • Accurate blending of gases in the O2 blender
  • Flow Control Valve
  • Auxiliary Gas Outlet
  • Pressure Control System
  • Flow Sensor
Category:

Description

Ventilator Dimensions

  • Height: 11 in
  • Width: 13.5 in
  • Depth: 10 in

Graphic Display Dimensions

  • Height: 9.5 in
  • Width: 13 in
  • Depth: 2.5 in
  • Weight: 5.5 lbs

Pedestal Stand Dimensions

  • Height: 40.5 in
  • Width: 24 in
  • Weight: 9 lbs.

Compressor Dimensions

  • Height: 36 in
  • Width: 22 in
  • Depth: 21.5 in
  • Weight: 11o lbs

Environmental

  • Temperature
    • Storage and Shipping -40 to 158 ºF (-40 to 70 ºC)
    • Checkout and Operating 50 to 104 ºF (10 to 40 ºC)
  • Altitude
    • Checkout, Operating, Transport and Storage 0 to 9,000 feet (14.7 to 10.5 PSIA/760 to 543 mm Hg)
  • Humidity
    • Storage and Shipping 0 to 99% Relative Humidity — Non-condensing
    • Checkout and Operating 0 to 95% Relative Humidity — Non-condensing

Controls

  • Mode: Flow Cycle AC, AC, SIMV/IMV, SIMV/PSV, Flow Cycled SIMV CPAP/PSV
  • Rate: 1 to 150 bpm
  • Inspiratory Time: 0.1 to 3.0 sec
  • PEEP: 0 to 30 cmH2O
  • Inspiratory Pressure: 0 to 72 cmH2O
  • Manual Breath: x1
  • Assist Sensitivity: 0.02 to 5.0 L/min
  • Over Pressure Relief: 15 to 75 cmH2O
  • % O2: 21 to 100%
  • Apnea Alarm (selectable): 5, 10, 20 or 30 sec

Monitors

  • Breath Rate: 0 to 255 bpm
  • Patient Initiated Indicator: LED
  • Minute Volume: 0 to 30.0 L/min
  • Tidal Volume: 0 to 500 ml (Inspired and Expired)
  • %Tube Lea:k 0 to 100%
  • Inspiratory Time: 0.1 to 3.10 sec
  • Expiratory Time: 0 to 99.9 sec
  • I:E Ratio: 9.1 to 1:9.9
  • Peak Inspiratory Pressure: 0 to 99 cmH2O
  • Mean Airway Pressure: 0 to 75.0 cmH2O
  • PEEP: 0 to 30.0 cmH2O
  • Air Pressure: 0 to 100 psig
  • O2 Pressure: 0 to 100 psig
  • Proximal Airway Pressure: 10 to 100 cmH2O (Gauge)
  • Hourmeter: 0 to 99,999 hours
  • Test: Push button

Alarms / Limits

  • High Breath Rate: 3 to 255 bpm
  • Low PEEP/CPAP: -5 to 30 cmH2O
  • Low Inspiratory Pressure: 0.25 (High Pressure Limit – Low PEEP/CPAP) + Low PEEP/CPAP
  • Patient Circuit: LED On/Off
  • Failed to Cycle: On/Off
  • Low Gas Supply: LED On/Off
  • Apnea: LED On/Off
  • Pressure Settings Incompatible: LED On/Off
  • Prolonged Inspiratory Pressure: LED On/Off
  • Flow Sensor: LED On/Off
  • Low Battery: LED On/Off
  • Alarm Silence: 60 sec
  • Visual Reset: Push Button
  • High Pressure Limit: 10 to 75 cmH2O
  • Line Power: Green/Red LED

Electrical

  • Voltage
    • 100 V – 80 to 110 VAC
    • 120V – 96 to 132 VAC
    • 220V – 176 to 242 VAC
    • 240V – 192 to 264 VAC
  • Current
    • 100V – 1.0 A maximum
    • 120V – 1.0 A maximum
    • 220V – 0.5 A maximum
    • 240V – 0.5 A maximum
  • Frequency
    • 100V – 50.60 Hz
    • 120V – 50/60 Hz
    • 220V – 50/60 Hz
    • 240V – 50/60 Hz
  • Fuses
    • 100/120V – T o.5 A, 5 x 20 mm
    • 230/240V – T 0.5 A, 5 x 20 mm
    • (For 220V operation, set the power entry module seclector switch to 230V setting)

Reviews

There are no reviews yet.

Be the first to review “Bear Cub 750 PSV”

Your email address will not be published.