l

Ut wisi enim ad minim veniam, quis laore nostrud exerci tation ulm hedi corper turet suscipit lobortis nisl ut

Recent Posts
2643-G and H Taft Avenue Pasay City Manila, PH 1300
26846 Oak Avenue Unit C Canyon Country, CA 91351
Image Alt

HP CodeMaster

The HP Codemaster XL combines a DC defibrillator / cardioscope, annotated recorder, and hands-off defibrillation capabilities into a single, high-performance unit. It operates on AC power or the internal battery supply and is available with a noninvasive pacemaker. The HP Codemaster XL is designed for high-use areas of the hospital. It’s perfect for operating rooms, intensive care units, cardiac care units, and emergency departments. It changes from zero to 360 joules in under five seconds and offers a variety of advanced options so you can easily customize it to meet your facility’s needs.

  • Defibrillator with ECG and recorder
  • Provides 1-2-3 operation
  • Built-in pediatric paddles under slide-off adult paddles
  • Preset heart rate alarms
  • High-capacity battery
  • Built-in diagnostics
Category:

Description

Dimensions

  • Height: 7.9” (20 cm)
  • Width: 11.8” (30 cm)
  • Depth: 15.6” (39.7 cm)
  • Weight: 24 lbs (10.9 kg)

Defibrillator

  • Waveform: Damped sinusoidal (Lown)
  • Output Energy: 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, and 360 joules
  • Charge Control: Push-button on apex paddle and on front panel
  • Charge Time: Less than 5 seconds to 360 joules with battery present. Less than 15 seconds to 360 joules on AC only
  • Armed Indicators: Charge done tone, charge done lamp on apex paddle, and available energy indicated on display
  • Paddle Contact Indicator (optional): 3-color LED bar graph array on STERNUM paddle indicates quality of defibrillator paddle contact before discharge
  • Paddles: Standard paddles are anterior/anterior, adult and pediatric. Adult electrodes (83 cm2) slide off to expose pediatric electrodes (21 cm2). Paddle cord is 10 ft (3 m). Full range of internal paddles available

Monitor

  • Inputs: ECG may be viewed through paddles or patient cable. Lead I, II, III, or PADDLES selectable. Additional leads (aVR, aVF, aVL, V Leads) and PADS are available. Monitor and recorder indicate selected ECG source
  • Lead Fault: LEADS OFF message and dashed baseline appear on monitor if a lead becomes disconnected
  • Common Mode Rejection: Greater than 100 dB measured as per AAMI standards for cardiac monitors (EC13)
  • Display Size and Type: 5 inch (12.7 cm) diagonal CRT for 4 seconds of ECG data on screen; non-fade, fixed trace. Scrolling trace is selectable
  • Sweep Speed: 25 mm/sec nominal
  • Frequency Response: 0.5 to 40 Hz
  • Heart Rate Display: Digital readout on monitor from 15 to 300 BPM.
  • Heart Rate Alarms: Three pre-set pairs of high and low heart rate alarm limits from 20 to 280 BPM. (Configurable pairs are optional.)
  • ECG Output: 1V/mV
  • Patient Cable Length: 10 ft (3 m)

Thermal Array Recorder

  • Event Summary (optional): Stores and prints 3 seconds pre- and 8 seconds post-critical event data for up to 28 events. Data retained after unit is turned off
  • Annotates: Time, date, HR, event marker, ECG mode, defibrillator mode, selected energy, actual delivered energy, peak current, and patient impedance
  • Speed: 25 mm/sec.
  • Paper Size: 50 mm by 30 m (100 ft)
  • Recorder Mode: Automatically documents events and ECG during defibrillation episodes. The recorder can be configured to run in either real-time or with a six-second delay
  • Frequency Response: 0.5 to 40 Hz or 0.05 to 150 Hz selectable

Battery

  • Type: Rechargeable sealed lead-acid battery. 4 Ah, 12 V nominal
  • Charge Time: 2 hours to 90% of full capacity. 18 hours to 100% capacity. Repeated charging to less than 100% will reduce useful life of battery.
  • Capacity: 2 1/2 hours monitoring or fifty (50) full-energy discharges or 1 hour monitoring and recording.
  • Battery Indicators: Illuminated LED indicates battery is charging. LOW BATTERY message appears on monitor when limited battery capacity remains.

External Pacemaker (Optional)

  • Current Pulse Amplitude: 10 mA to 200 mA
  • Pulse Width: 20 msec
  • Rate: 40 ppm to 180 ppm
  • Modes: Demand or fixed rate
  • Refractory Period: 40 to 80 ppm 340 msec; 90 to 180 ppm 240 msec

SpO2 (Optional)

  • Measurement Range: 0 to 100%
  • Accuracy with HP M1190A Sensor: 1 standard deviation, 65-80%: ±2.5%, 80- 100%: ±1.5%, resolution: 1%
  • Averaging: 8 beats
  • SpO2 Alarm Limits — Range: 100/90, 100/85, 100/80
  • SpO2 Alarm Delay: Ten seconds after value drops below the low alarm setting
  • INOP Alerts: Triggered by disconnected sensor, noisy signal, light interference oralow signal
  • Pulse Rate Measurement Range: 30 to 300 bpm ± 1%; resolution 1 bpm
  • Pulse Amplitude Indicator: Indicates pulsatile activity

Advisory Mode (Optional)

  • Analysis time: Seven to ten seconds
  • Output Energy (Delivered): factory default protocol 200J, 200J, 360J
  • Analysis Control: Push-button on front panel
  • Charge Time: Less than 5 seconds to 360 joules with battery present. Less than 15 seconds to 360 joules on AC only.
  • Armed Indicators: Charge done tone and available energy indicated on display
  • Advisory Event Summary: Stores approximately 200 events and 50 ECG strips. Data retained after instrument turned off.

Reviews

There are no reviews yet.

Be the first to review “HP CodeMaster”

Your email address will not be published.